Clean the threads of the studs with 8M8060 Quick Cure Primer. Then put 9S3265 Retaining Compound on the threads before installing them.

(1) Torque for stud for the filler cap … 40 ± 5 lb. ft.(55 ± 7 N·m)

(2) 2S3080 Pressure Relief Cap:

Pressure valve must not leak at … 11.9 psi(82 kPa)

Pressure valve must be open at … 15 psi(105 kPa)

Vacuum valve must be open at a pressure below atmospheric of … 0.6 psi(4 kPa)or 1.22 in. Hg (31.0 mm Hg) or 16.6 in. H2O (422 mm H2O)

Tightening Procedure For Typical Two-Row Tank