26SI Series Alternator – Starter Solenoid

Delco-Remy Starter Solenoid

4M1812 24V (Delco-Remy Number 1119848), 3T3421 24V (Delco-Remy Number 1115559), 3T4704 24V (Delco-Remy Number 1115557)

Current consumption (draw):

Current pull in windings at 5V … 10 to 11.5A

Current pull in windings at 20 to 24V … 40 to 55.2A

Current hold in windings at 20 to 24V … 8.2A

7T8854 24V (Delco-Remy Number 1115607)

Current consumption (draw):

Pull in windings at 5V … 9 to 11.5A

Hold in windings at 20 (max.) … 6.8A

Prestolite Starter Solenoid

9S7976 24V (prestolite Number SAT-4103)

Current consumption (draw):

Current pull in windings at 12V … 23.2 to 26.6A

Current pull in windings at 20 to 24V … 38.6 to 52.4A

Current hold in windings at 12V … 4.1 to 4.8A

Current hold in windings at 20 to 24V … 6.8 to 9.6A

3T3369 24V (Prestolite Number SAT-4105)

Current consumption (draw) at 21°C (70°F):

Pull-in windings at 12V … 23.2 to 26.6A

Hold-in windings at 12V … 4.1 to 4.8A

3T8635 24V (Prestolite Number SAT-4107)

Current consumption (draw):

Pull in windings at 12V … 23.2 to 26.6A

Pull in windings at 20V … 38.7 to 44.4A

Hold in windings at 12V … 4.1 to 4.8A

Hold in windings at 20V … 6.8 to 8.0A

Bosch Starter Solenoid

3T868 24V (Bosch Number 0-331-410-002)

Current consumption (draw):

Pull in windings at 20V … 35.3 to 39.0A

Hold in windings at 20V … 5.5 to 6.1A