26SI Series Alternator – Field Winding – Test

The illustrations below show The M1 series alternator (35 amps).

Field Winding Continuity Test




    Illustration 1 g00825532

    Field Winding Continuity Test

    (6) Field winding leads

  1. Remove the rear cover.
  1. If the alternator has a capacitor, remove the capacitor.
  1. Remove the regulator.
  1. Connect the multimeter leads across field winding leads (6). This is shown in Illustration 1.
  1. Measure the resistance between the field winding leads.

    Expected Results:

    M1 Series Alternators … 9 ± 0.1 ohms
    HDB Series Alternators … 8.2 ± 0.4 ohms

    Results:

    OK – The resistance is within tolerance. The field winding is normal. STOP.

    NOT OK – The resistance is above tolerance. The field winding has an open circuit. Replace the field winding. STOP.

    NOT OK – The resistance is below tolerance. The field winding has a short circuit. Replace the field winding. STOP.

Field Winding Ground Test




    Illustration 2 g00825533

    Field Winding Ground Test

    (6) Field winding leads

    (7) Rear frame

  1. The rear cover, the capacitor, and the regulator remain removed from the alternator.
  1. Connect the multimeter leads across rear frame (7) and one field winding lead (6). This is shown in Illustration 2.
  1. Measure the resistance.

    Expected Result: The resistance is greater than 100000 ohms.

    Results:

    OK – The resistance is greater than 100000 ohms. Repeat steps 1 to 3 for the other field winding lead (6). If all of the results are OK, the stator is normal. STOP.

    NOT OK – The resistance is NOT greater than 100000 ohms. The field winding lead is shorted to the frame. Replace the field winding. STOP.

Posted in D6Tagged