153 & 163 HYDRAULIC CONTROL – Oil Filter

(1) Torque for bolt … 60 ± 5 lb.ft.(80 ± 7 N·m)

(2) 7F9802 Spring for bypass valve:

Length under test force … 1.875 in.(47.63 mm)

Test force … 23.9 ± 1.9 lb.(110 ± 8 N)

Free length after test … 3.312 in.(84.12 mm)

Outside diameter … 1.250 in.(31.75 mm)